Volk Mag Plus Iridectomy Laser Lens

Volk’s range of iridotomy lenses provide high-detail views of the iris to recognize the best location for treatment such as iris crypts while the optics ensure that laser energy is efficiently transferred for effective treatment of closed angle glaucoma. The Mag Plus takes its name from the large magnification button with the lens body which […]
Volk Rapid SLT Laser Lens

The Rapid SLT is equipped with four totally internal reflective surfaces that provide high-detail views of all four quadrants of the angle structures. Thus, SLT procedure time is reduced in half as the need to rotate the lens on the patient’s eye is drastically minimized thus enhancing patient comfort. The contact surface is designed to provide patient comfort while maintaining […]
Volk Vold Gonio

Primary Application – Direct Views for Micro-Invasive Glaucoma Surgery (MIGS) and all Intraoperative Gonio Procedures Stabilization ring provides control of the globe Minimizes corneal pressure to prevent anterior chamber distortion Visualizes angle in primary phaco position with minimal microscope and head adjustments Fully steam sterilizable Image Magnification Contact Diameter Ring Diameter Handle Length 1.20x 9 […]
Volk HR Centralis Lens

This lens gives detailed, high magnification views of the posterior pole for performing focal/Grid Laser procedures. Building on the optical capabilities of the Area Centralis, the H-R Centralis is enhanced with small pupil capabilities and fabricated using a high grade, low dispersion glass offering high resolution views of the posterior pole. High magnification for detailed […]
Volk Direct Image Mid Field SSV Lens (ACS)

Primary Application – Wide Field Direct Image Vitreoretinal Surgery Bi-concave design provides widest field available in a direct image lens Can be used for air/gas exchange procedures Steam sterilizable for reduced processing time Field of View Image Magnification 40° 0.50x
Volk Direct Image Flat SSV Lens (ACS)

Primary Application – Routine Direct Image Vitreoretinal Surgery of the Central Retina Delivers high resolution direct image of the central retina Steam sterilizable for reduced processing time Field of View Image Magnification 30° 0.92x
Volk DynaView Lens

Primary Application – Treatment of Retinopathy of Prematurity Enhanced design provides wide field imaging out to the ora serrata Minified housing facilitates extension of instruments Reduced contact size ideal for pediatric examination Field of View Image Magnification 95° / 127° 0.39x
Volk Direct Image High Mag SSV Lens (ACS)

Primary Application – High Magnification Direct Image Vitreoretinal Surgery of the Central Retina Delivers high resolution, high magnification direct image of the central retina Steam sterilizable for reduced processing time Field of View Image Magnification 28° 1.50x
Volk Mini 4-Mirror ANF+ Lens

4-Mirror, Acrylic Design Smaller, lighter-weight design facilitates easy manipulations within the orbit Advanced no fluid (ANF+) flange does not require coupling fluid during routine gonioscopy Mirror Angles Image Magnification Laser Spot Size Contact Diameter 4 x 62° 1.0x 1.0x 15 mm
Volk Super Macula Lens

Primary Application – Highest Magnification Indirect Viewing and Treatment of the Central Retinal High resolution, highest magnification imaging of the central retina Ideal for macular holes, epiretinal membranes, and submacula surgery 2x field of view compared to plano/concave direct image lenses Field of View Image Magnification 64° / 77° 1.03x